-
ST0670, ST0670
Display the relevant hazard warning signs.
-
ST0877
Engage with a range of stakeholders involved in the project, including the communities affected by it.
-
ST0414
Ensure all access platforms are used where necessary and that all relevant health and safety and legal requirements have been met when storing and using paints and adhesives whilst also maintaining all tools and equipment
-
ST0414
Ensure all tasks meet the requirements laid down in any instructions/plans and that tasks meet any budgets set
-
ST0414
Ensure all testing of installations installed and maintenance is carried out in a safe manner and that all relevant health and safety and legal requirements have been met
-
ST0651
Ensure compliance with British Standards BS (Lightning Protection) and BS (Earthing) is maintained at all times.
-
ST0091
Ensure compliance with equality, diversity & inclusion (EDI) and ethical standards
-
ST0091
Ensure compliance with health, safety & welfare requirements, apply safe systems of work, such as Common Safety Methods (CSM), and identify hazards and mitigate risks in their own work
-
ST0414
Ensure legal requirements are met when using plant, carry out all necessary paperwork and ensure that all safety precautions are taken and correct Personal Protective Equipment is worn
-
ST0743
Ensure structural stability using structural supports e.g. acrows or strong boys. Ensuring that the lintel is present and remains undamaged or that a new one is installed above the window
-
ST0670
Ensure the correct Personal Protective Equipment is readily available prior to attending site.
-
ST0670
Ensure work is carried out in line with industry standards - PCA Codes of Practice (Damp-proofing Barriers - Tanking in Association with Chemical Damp-proofing courses) and Guidance documents.
-
ST0670
Ensure work is carried out in line with industry standards - PCA Codes of Practice and Guidance documents (Code of Practice for the Investigation and Control of Wood Destroying Insects and Fungi in Buildings, Fungal Decay in Buildings).
-
ST0670
Ensure work is carried out in line with industry standards - PCA Codes of Practice and Guidance documents (Code of Practice for the Investigation and Control of Wood Destroying Insects and Fungi in Buildings, Wood Destroying Insects in Buildings).
-
ST0670
Ensure work is carried out in line with industry standards - PCA Codes of Practice and Guidance documents (Guidance Note on the Party Wall Act).
-
ST0670
Ensure work is carried out in line with industry standards - PCA Codes of Practice and Guidance documents (Hygroscopic Salts and Rising Dampness; Plastering in Association with Damp-Proof Coursing; Chemical Damp-Proof Course Insertion - the attendant problems;Guidance Note Party Wall ; Code of Practice for the Investigation and Control of Dampness in Buildings).
-
ST0670
Ensure work is carried out in line with industry standards - PCA Codes of Practice and Guidance documents.
-
ST0670
Ensure work is carried out in line with industry standards and relevant legislation and procedures.
-
ST0265
Erect components such as modular units, panelised elements and secondary structures e.g.: support systems and balconies, bracketry, columns, lintels, external and internal fire stopping, service connections, internal fabric finishing materials according to specifications and drawings.
-
ST0265
Erect components such as panels, large format block work, staircases, columns, flooring, lintels and pods according to specifications and drawings.
-
ST0264
Erect inclined roofs with gables, joists, roof coverings and roof components.
-
ST0263
Erect inclined roofs with gables, roof verges and eaves, including finishings, joists and roof coverings, dormers and features.
-
ST0265
Erect timber frame panels to create walls on-site according to specifications and drawings.
-
ST0265
Erect timber roof structures and components, in-situ roofs and pre-assembled roof structures according to drawings and specifications.
-
ST0821
Establish daily and weekly tasks and organise own work with emphasis on efficiency and safety.
-
ST0651
Establish systems and equipment to create a safe working environment in line with organisational procedures, site requirements and budgets.
-
ST0821
Establish the suitability of the work area including PPE equipment, scaffolding, ladders and an understanding of how any risk assessment affects them.
-
ST0742
Evaluate and manage the needs of people, place and nature
-
ST0821
Evaluate condition of roof and prepare roof for thatching
-
ST0742
Evaluate, assess and advise on environmental impact and opportunities for regeneration, flood management, sustainable transport and protection of historical sites and the natural environment
-
ST0736
Extract and use information from the machine's operator's manual, site plans and drawings and verbal communication
-
ST0096
Finish plasterboard surfaces by tape and joint or finishing plasters.
-
ST0388
Fit doors, doorsets, and ironmongery, fix trims/mouldings, form junctions
-
ST0388
Fit integral glass, frames, trims and mouldings, install glass panels and blinds
-
ST0821
Fix appropriate thatching materials to roof features with correct depth over fixings and adequate tensions.
-
ST0743
Fix fenestration units in place, making sure they are plumb, level and secure using a range of tools and technologies e.g. spirit level, laser level, through frame fixings, one way screws, Thread cutting screws or machine screws if working with aluminium. Follow guidance and manufacturers requirements or systems manuals
-
ST0821
Fixing appropriate thatching materials to basic roof structure with correct depth over fixings and adequate tension.
-
ST0265
Fixing temporary works for stability and safe access
-
ST0265
Follow connection details and ensure it has been installed according to specification
-
ST0331
Follow due diligence in providing advice to clients
-
ST0669
Follow instructions and take responsibility for minimising risk and ensuring own safety and the safety of the team
-
ST0670
Follow instructions to minimise risk and ensure the safety of the team and customer
-
ST0614
Follow manufacturer's instructions to correctly assemble systems from component parts
-
ST0265
Follow organisational procedures to prepare the exterior building to meet customer specifications e.g. shot blasting, repainting the exterior, windows, stairways, linkways, doors, ironmongery, trims.
-
ST0877
Follow up enquiries via phone/site visit, encouraging parties to sign access licences and respond to any concerns they may have.
-
ST0096
For external rendering fix and form stops/expansion joints and bell casts to form drips for weathering
-
ST0096
For internal plastering cut and fix a range of standard and thin coat beads/trims to form true surfaces such as corners/returns for openings,
-
ST0388
Form builders works holes and openings for windows and doors
-
ST0388
Form framed and frameless beam and column in accordance with specification & manufactures instructions
-
ST0388
Form junctions, abutments and angles according to specification & manufactures instructions